Fronter's Opel + Opel Frontera brand Cars + Current leaving and service + Engine + cooling and heating Systems + Power supply system and release + engine Electric equipment + Coupling + Manual box of gear shifting + Driveshafts, main transfer - Brake system Brake mechanisms of forward wheels Brake mechanism of back wheels Disk brakes of back wheels Main brake cylinder Air removal from brake system Vacuum amplifier of a brake Parking brake Pressure regulator Brake hoses of forward and back brake mechanisms Anti-blocking system (ABS) + Suspension bracket and steering + Body + Onboard electric equipment + Governing bodies and operation + electric equipment Schemes
|
Pressure regulator
The pressure regulator is not subject to repair and in case of defects in work is replaced. Serviceability of a regulator of pressure can a life is checked by means of the special device in the conditions of Opel firm repair trucks. Fastening of a regulator of pressure is shown on an illustration.
Removal and installation of a regulator of pressure
Replacement of a regulator is carried out as follows:
Removal
PERFORMANCE ORDER |
1. Lift and establish on supports a back part of the car. |
2. Disconnect from a regulator brake pipelines (1), (2) and (3). To expel pouring out of brake liquid from system, it is necessary to unscrew a tank stopper on the main cylinder, to fill in liquid to the top level, to put from above polyethylene and again to wrap a stopper. The disconnected pipelines stop up for a hit exception in dirt system. |
3. Disconnect from the bridge шплинт, a nut (5), a washer (6) and the holder (7). |
4. Unscrew nuts (4), remove two washers and remove a regulator of pressure and spring knot. |
|
Installation
The regulator as follows is established:
PERFORMANCE ORDER |
1. Establish a regulator and spring knot and fix them two washers and nuts (4). |
2. Nuts tighten the moment of 12 Nanometers. |
3. Establish the holder (7), a washer (6) and a nut (5) with the shplinty. |
4. A nut tighten the moment of 13 Nanometers. |
5. At installation of the holder watch that his convex party was turned to the rubber plug. |
6. Connect to the unions brake pipelines (1) and (3). |
7. A cap nut of connections tighten the moment of 16 Nanometers. |
8. Connection carry out carefully since it has a small carving. |
9. In summary fill in liquid in system and remove from it air as it is described above. |
10. Check in a repair truck action of a regulator of pressure. |
|
|
|